發(fā)電機(jī)組

柴油發(fā)電機(jī)組自動(dòng)化高壓柜

  

GFZ系列自動(dòng)化柴油發(fā)電機(jī)組

一、產(chǎn)品詳細(xì)介紹
\
A.顯示:三相電壓、三相電流、發(fā)電機(jī)功率、功率因數(shù)、頻率、控制用蓄電池電壓、浮充電電流、運(yùn)行時(shí)間計(jì)時(shí)。 

 

  

B:三相電壓、三相電流、發(fā)電機(jī)功率、功率因數(shù)、頻率、控制用蓄電池電壓、浮充電電流、運(yùn)行時(shí)間計(jì)時(shí)。 

 

  B.指示:市電電源指示、發(fā)電機(jī)組電源指示、供電指示、各類故障報(bào)警指示。 

  C.狀態(tài)選擇:自動(dòng)/手動(dòng)/試運(yùn)行。 

  1.自動(dòng):準(zhǔn)狀態(tài)自動(dòng)控制、市電狀態(tài)自動(dòng)檢測(cè)、機(jī)組自動(dòng)啟動(dòng)、自動(dòng)投網(wǎng)、自動(dòng)退網(wǎng)、自動(dòng)停機(jī)、故障自動(dòng)跳閘、停機(jī)、報(bào)警。

  2.手動(dòng):手動(dòng)啟動(dòng)、手動(dòng)合閘、分閘、停機(jī) 

  3.試運(yùn)行:在市電有電狀態(tài)下,每周一次對(duì)機(jī)組實(shí)行自動(dòng)化運(yùn)行,確保機(jī)組在良好的備用狀態(tài)。 

  D.調(diào)節(jié): 

  1.發(fā)電機(jī)電壓自動(dòng)調(diào)節(jié)和手動(dòng)微調(diào)。

  發(fā)電機(jī)電壓自動(dòng)調(diào)節(jié)精度±0.5%Ve(注:Ve-額定電

  發(fā)電機(jī)電壓手動(dòng)微調(diào)范圍 ±0.5%Ve 

  2.浮充電調(diào)節(jié)。

  0~5A浮充電(對(duì)控制用蓄電池)電流可調(diào)節(jié)。

  蓄電池電壓DC12/24V 

  E.準(zhǔn)狀態(tài)控制系統(tǒng): 

  自動(dòng)預(yù)加熱系統(tǒng)

  輸出電壓AC220V

  輸出功率1.5KW/臺(tái)

  自動(dòng)控制溫度50~55℃(機(jī)組溫度)

  在自動(dòng)狀態(tài),機(jī)組時(shí)刻準(zhǔn)備市電失電時(shí)自動(dòng)啟動(dòng),在≤8S內(nèi)自動(dòng)投網(wǎng),帶滿負(fù)荷運(yùn)行。機(jī)組必須在準(zhǔn)備狀態(tài)時(shí),通過水冷卻系統(tǒng)預(yù)加熱、自循環(huán)、溫度自動(dòng)控制,實(shí)現(xiàn)機(jī)組50~55℃溫度。 

  F.市電自動(dòng)檢測(cè):

  在自動(dòng)狀態(tài),通過外開關(guān)信號(hào),對(duì)市電狀態(tài)自動(dòng)長期檢測(cè)、判別。一旦市電有故障、失電時(shí),即刻可進(jìn)入自動(dòng)啟動(dòng)狀態(tài)。 

  G.機(jī)組自動(dòng)啟動(dòng)、自動(dòng)投網(wǎng)、自動(dòng)退網(wǎng)、自動(dòng)停機(jī)系統(tǒng):

  當(dāng)機(jī)組在自動(dòng)狀態(tài)下,市電故障失電經(jīng)系統(tǒng)3S確認(rèn),自動(dòng)啟動(dòng)機(jī)組(啟動(dòng)三次為一個(gè)循環(huán))。當(dāng)額定電壓和額定轉(zhuǎn)速時(shí),自動(dòng)合閘投網(wǎng)、供電。自啟動(dòng)投網(wǎng)供電時(shí)間≤12S。當(dāng)市電恢復(fù)正常后,經(jīng)系統(tǒng)3S確認(rèn),機(jī)組自動(dòng)跳閘退網(wǎng),延時(shí)3分鐘,自動(dòng)停機(jī),并自動(dòng)進(jìn)入下一個(gè)自動(dòng)啟動(dòng)的準(zhǔn)備狀態(tài)。 

  H.自動(dòng)保護(hù):

  具有過載、短路、高水溫、低油壓、欠電壓、油高溫、超速保護(hù)。

  具有自動(dòng)跳閘、停機(jī)功能。

  具有過載、高水溫、低油壓、自啟動(dòng)失敗、超速、油高溫

  故障自動(dòng)聲光報(bào)警。 

  I.系統(tǒng)說明:

  系統(tǒng)采用高可靠性電氣產(chǎn)品,自動(dòng)控制、自動(dòng)啟動(dòng)、自動(dòng)停機(jī)等自動(dòng)控制,工業(yè)電腦采用中外合資PLC控制電腦系統(tǒng),確保運(yùn)行的可靠性。 

  二、市電、機(jī)組自動(dòng)切換系統(tǒng)功能:

      該系統(tǒng)具有市電、機(jī)組兩路電源自動(dòng)切換供電的功能,主要實(shí)現(xiàn)市電與機(jī)組電源的自動(dòng)切換。市電正常狀態(tài)下,系統(tǒng)具有市電優(yōu)先供電的功能,當(dāng)市電失電時(shí),系統(tǒng)能自動(dòng)倒換之機(jī)組側(cè),由機(jī)組向負(fù)載自動(dòng)供電;當(dāng)市電恢復(fù)正常時(shí),系統(tǒng)能自動(dòng)倒換之市電側(cè),由市電向負(fù)載自動(dòng)供電,具有市電優(yōu)先供電功能。

  根據(jù)發(fā)電機(jī)組與市電的數(shù)量不同,可分為:?jiǎn)螜C(jī)組與單市電的切換、單機(jī)組與雙市電的切換、雙機(jī)組與單市電的切換、雙機(jī)組與雙市電的切換。它們的功能如下: 

  A.單機(jī)組與單市電的切換:

  參數(shù)顯示功能:市電電壓、發(fā)電機(jī)電壓、負(fù)載電流。

  狀態(tài)顯示功能:市電正常/故障、發(fā)電機(jī)運(yùn)行/故障、市電/發(fā)電機(jī)帶載。

  手動(dòng)控制功能:手動(dòng)/自動(dòng)/維修、發(fā)電機(jī)/市電帶載。

  自動(dòng)控制功能:市電故障,延時(shí)確認(rèn)(時(shí)間可調(diào)),發(fā)出起動(dòng)機(jī)組指令,機(jī)組起動(dòng)運(yùn)行正常后,發(fā)電機(jī)帶載;市電恢復(fù),延時(shí)確認(rèn)(時(shí)間可調(diào)),市電帶載,機(jī)組空載運(yùn)行3分鐘(可調(diào))后自動(dòng)停機(jī)。 

  B.單機(jī)組與雙市電的切換:

  參數(shù)顯示功能:一路市電電壓、二路市電電壓、發(fā)電機(jī)電壓、負(fù)載電流。

  狀態(tài)顯示功能:一路市電正常/故障、二路市電正常/故障、發(fā)電機(jī)運(yùn)行/故障、一路市電/二路市電/發(fā)電機(jī)帶載。

  手動(dòng)控制功能:手動(dòng)/自動(dòng)/維修、主/備用市電選擇、發(fā)電機(jī)/一路市電/二路市電帶載。

  自動(dòng)控制功能:主用市電故障,延時(shí)確認(rèn)(時(shí)間可調(diào)),備用市

  電帶載;兩路市電都發(fā)生故障,則發(fā)出起動(dòng)機(jī)組指令,機(jī)組起動(dòng)運(yùn)行正常后,發(fā)電機(jī)帶載;市電恢復(fù),延時(shí)確認(rèn)(時(shí)間可調(diào)),市電帶載,機(jī)組空載運(yùn)行3分鐘(可調(diào))后自動(dòng)停機(jī)。 

  C.雙機(jī)組與單市電的切換:

  參數(shù)顯示功能:市電電壓、一號(hào)發(fā)電機(jī)電壓、二號(hào)發(fā)電機(jī)電壓、負(fù)載電流。

  狀態(tài)顯示功能:市電正常/故障、一號(hào)發(fā)電機(jī)運(yùn)行/故障、二號(hào)發(fā)電機(jī)運(yùn)行/故障、市電/一號(hào)發(fā)電機(jī)/二號(hào)發(fā)電機(jī)帶載。

  手動(dòng)控制功能:手動(dòng)/自動(dòng)/維修、主/備用發(fā)電機(jī)選擇、一號(hào)發(fā)電機(jī)/二號(hào)發(fā)電機(jī)/市電帶載。

  自動(dòng)控制功能:市電故障,延時(shí)確認(rèn)(時(shí)間可調(diào)),發(fā)出起動(dòng)主用機(jī)組指令,主用機(jī)組起動(dòng)運(yùn)行正常后帶載;如主用機(jī)組在起動(dòng)或運(yùn)行過程中發(fā)生故障,則自動(dòng)起動(dòng)備用機(jī)組,備用機(jī)組起動(dòng)運(yùn)行正常后帶載;市電恢復(fù),延時(shí)確認(rèn)(時(shí)間可調(diào)),市電帶載,機(jī)組空載運(yùn)行分鐘(可調(diào))后自動(dòng)停機(jī)。 

  D.雙機(jī)組與雙市電的切換:

  參數(shù)顯示功能:一路市電電壓、二路市電電壓、一號(hào)發(fā)電機(jī)電壓、二號(hào)發(fā)電機(jī)電壓、負(fù)載電流。

  狀態(tài)顯示功能:一路市電正常/故障、二路市電正常/故障、一號(hào)發(fā)電機(jī)運(yùn)行/故障、二號(hào)發(fā)電機(jī)運(yùn)行/故障、一號(hào)發(fā)電機(jī)/二號(hào)發(fā)電機(jī)/一路市電/二路市電帶載。

  手動(dòng)控制功能:手動(dòng)/自動(dòng)/維修、主/備用發(fā)電機(jī)選擇、主/備手市電選擇、一號(hào)發(fā)電機(jī)/二號(hào)發(fā)電機(jī)/一路市電/二路市電帶載。

  自動(dòng)控制功能:主用市電故障,延時(shí)確認(rèn)(時(shí)間可調(diào)),備用市電帶載;兩路市電都發(fā)生故障,延時(shí)確認(rèn)(時(shí)間可調(diào)),發(fā)出起動(dòng)主用機(jī)組指令,主用機(jī)組起動(dòng)運(yùn)行正常后帶載;如主用機(jī)組在起動(dòng)或運(yùn)行過程中發(fā)生故障,則自動(dòng)起動(dòng)備用機(jī)組,備用機(jī)組起動(dòng)運(yùn)行正常后帶載;市電恢復(fù),延時(shí)確認(rèn)(時(shí)間可調(diào)),市電帶載,機(jī)組空載運(yùn)行3分鐘(可調(diào))后自動(dòng)。

  系統(tǒng)采用中外合資愛捷ATS切換開關(guān),實(shí)現(xiàn)機(jī)電互鎖確保運(yùn)行的可靠性。 

  三、自并車、自動(dòng)調(diào)頻調(diào)載系統(tǒng)功能: 

  A.該系統(tǒng)功能具有手動(dòng)并網(wǎng)/自動(dòng)并網(wǎng)/“0”位置叁套系統(tǒng)及選擇。

  當(dāng)系統(tǒng)在手動(dòng)并車狀態(tài)下,通過同步表實(shí)現(xiàn)兩臺(tái)機(jī)組手動(dòng)并網(wǎng)。并聯(lián)運(yùn)行后,可通過自動(dòng)調(diào)頻調(diào)載裝置,實(shí)現(xiàn)機(jī)組運(yùn)行過程中的自動(dòng)調(diào)頻、自動(dòng)調(diào)載。

  當(dāng)系統(tǒng)在“0”位狀態(tài)下,在自動(dòng)狀態(tài)下兩臺(tái)機(jī)組在市電失電后同時(shí)啟動(dòng)機(jī)組,只有一臺(tái)機(jī)組實(shí)現(xiàn)自動(dòng)投網(wǎng)供電,另一臺(tái)機(jī)組延時(shí)3分鐘停機(jī)。若已投網(wǎng)機(jī)組發(fā)生故障,立即啟動(dòng)另一臺(tái)機(jī)組并投網(wǎng)供電。 

  B.當(dāng)系統(tǒng)在自動(dòng)并車狀態(tài)下:在自動(dòng)狀態(tài)下兩臺(tái)機(jī)組在市電失電后同時(shí)啟動(dòng)機(jī)組,甲臺(tái)機(jī)組實(shí)現(xiàn)自動(dòng)投網(wǎng),當(dāng)供電負(fù)載小于一臺(tái)機(jī)組額定功率時(shí),乙臺(tái)機(jī)組延時(shí)3分鐘停機(jī),當(dāng)已運(yùn)行甲臺(tái)機(jī)組連續(xù)工作8小時(shí),乙臺(tái)機(jī)組會(huì)立即啟動(dòng),實(shí)現(xiàn)二臺(tái)機(jī)組自動(dòng)并網(wǎng),并將供電負(fù)載轉(zhuǎn)移到乙臺(tái)機(jī)組上,甲臺(tái)機(jī)組退網(wǎng),并延時(shí)3分鐘停機(jī)。 

  C.當(dāng)供電負(fù)載連續(xù)1分鐘大于一臺(tái)機(jī)組額定功率時(shí),另一臺(tái)機(jī)組會(huì)立即啟動(dòng)并并網(wǎng)供電。該調(diào)頻調(diào)載裝置確保兩臺(tái)機(jī)組負(fù)載分配均勻。

  該功能可根據(jù)用戶要求編程。 

  D.該系統(tǒng)并具有逆功率保護(hù)。系統(tǒng)采用高可靠性電氣產(chǎn)品,自動(dòng)控制、自動(dòng)啟動(dòng)、自動(dòng)投網(wǎng)、自動(dòng)退網(wǎng)、自動(dòng)停機(jī)等自動(dòng)控制,工業(yè)電腦采用工業(yè)控制電腦PLC系統(tǒng),確保運(yùn)行的可靠性。 

  E.自動(dòng)并車裝置、自動(dòng)調(diào)頻調(diào)載裝置,均采用品質(zhì)可靠的產(chǎn)品。

  注:以上為柴油發(fā)電機(jī)組自動(dòng)化,并車,切換等全部功能介紹,具體客戶的機(jī)型選擇根據(jù)客戶需要進(jìn)行安排。我公司一定致力給您提供完美的自動(dòng)化配置,您的滿意是本公司最大的追求!

 
\\\\
產(chǎn)品說明:

 

     自動(dòng)化柴油發(fā)電機(jī)組是設(shè)計(jì)有先進(jìn)的控制系統(tǒng),采用專用的程序控制器,及先進(jìn)的ATS為核心的高性能數(shù)字化、自動(dòng)化發(fā)電機(jī)組。產(chǎn)品從10KW-5000KW機(jī)組在無人值守的情況下自動(dòng)實(shí)現(xiàn)機(jī)組的啟動(dòng)與停機(jī),市電與網(wǎng)電的自動(dòng)切換,機(jī)組運(yùn)行狀態(tài)的自動(dòng)監(jiān)控,產(chǎn)品技術(shù)性能優(yōu)越、質(zhì)量可靠,多年來產(chǎn)品成為自動(dòng)化機(jī)組的領(lǐng)航者,出口量全國名列前茅。

  性能介紹

  1、自動(dòng)啟動(dòng)及投入功能 

      當(dāng)市電電網(wǎng)停止供電或市電電壓低于80%的額定值時(shí)機(jī)組將自動(dòng)啟動(dòng),啟動(dòng)成功后,給負(fù)載供電,一次啟動(dòng)成功的整個(gè)過程控制在15秒內(nèi),具有遠(yuǎn)端接口,可設(shè)置啟動(dòng)延時(shí),實(shí)現(xiàn)發(fā)電機(jī)組自動(dòng)啟動(dòng)和停機(jī)。

  2、自動(dòng)退出功能 

   發(fā)電機(jī)組在自動(dòng)狀態(tài)進(jìn)行自發(fā)電輸出期間,如果市電恢復(fù)并經(jīng)30秒確認(rèn)后,機(jī)組開始執(zhí)行自動(dòng)退出程序,機(jī)組將首先切斷負(fù)載,恢復(fù)市電供電,然后冷機(jī)運(yùn)行2分鐘后自動(dòng)停機(jī)。若冷機(jī)運(yùn)行期間,市電停止供電,則機(jī)組自動(dòng)調(diào)高速,恢復(fù)對(duì)負(fù)載供電。

  3、預(yù)告警/故障保護(hù)功能 

   電池電壓低,充電失敗,過流,油壓低、水溫高等具有預(yù)告警功能,即數(shù)值在告警不停機(jī),此時(shí)告警燈閃爍;當(dāng)數(shù)值超過停機(jī)值時(shí),油機(jī)產(chǎn)生故障并且停機(jī)。 

   轉(zhuǎn)速低、超速、頻率超限,電壓超限、急停、啟動(dòng)失敗有故障保護(hù)功能,如果某路模擬量輸入值大于上限或小于下限,開始對(duì)應(yīng)的過高/過低延時(shí),延時(shí)結(jié)束后,數(shù)值扔未恢復(fù)正常,油機(jī)立即故障停機(jī),告警燈長亮。

      上述各種報(bào)警信號(hào)均有自鎖功能,只有現(xiàn)場(chǎng)人員排除故障后,按下“停機(jī)”鍵才會(huì)使系統(tǒng)恢復(fù)正常。

  4、自動(dòng)充電功能 

   機(jī)組在市電或自發(fā)電期間,可對(duì)啟動(dòng)控制電瓶進(jìn)行自動(dòng)充電。充電系統(tǒng)采用開關(guān)電源,它可對(duì)電瓶實(shí)現(xiàn)兩階段方式充電。在充電第一階段,電瓶容量較低時(shí),采用恒流6ADC充電,當(dāng)電瓶電壓到26.5VDC轉(zhuǎn)入恒壓充電,并一直保持浮充電。當(dāng)電瓶充足電時(shí),充電電流自動(dòng)為零。

  5、手動(dòng)功能 

   機(jī)組控制系統(tǒng)的面板上有自動(dòng)和手動(dòng),當(dāng)系統(tǒng)工作在手動(dòng)狀態(tài)時(shí),可實(shí)現(xiàn)對(duì)機(jī)組的啟動(dòng),高低速裝換、供電、停機(jī)、報(bào)警信號(hào)燈光試驗(yàn)報(bào)警解除自發(fā)電分閘和合閘,市電合閘等操作。緊急停車旋鈕在自動(dòng)與手動(dòng)狀態(tài)下均生效。非常緊急情況,切勿用此按鈕。 

  6、其他功能概述 

      使用動(dòng)畫圖標(biāo)式告警、故障顯示、高亮度、多色液晶顯示器顯示參數(shù);自動(dòng)記錄機(jī)組運(yùn)行時(shí)間;結(jié)構(gòu)緊湊合理、性能穩(wěn)定可靠。

  

Automatic diesel generating set switch

Automatic switch

 

  

A detailed introduction, product
\
A. display: three-phase voltage, three-phase current, generator power, power factor, frequency, control the voltage of the battery float charging current, operation time, time.

 

  

B : three-phase voltage, three-phase current, generator power, power factor, frequency, control the voltage of the battery float charging current, operation time, time.

 

   B. indicator: the city power supply indicator, generator power indicator, power supply indicator, all kinds of fault alarm indication.

   The state of the C. selection: automatic / manual / trial operation.

   1: automatic control, automatic quasi state city electricity state automatic detection, automatic start, automatic cast net unit, automatic back network, automatic shutdown, automatic shutdown, fault alarm, trip.

   2 manual: manual start, manual closing, tripping, stop

   The 3 trial operation: there is power in the state of city electricity, once a week to implement automatic operation of the unit, ensure the unit in good standby.

   D. regulation:

   1 generator automatic voltage adjustment and manual adjustment.

   Automatic voltage regulation accuracy + 0.5%Ve (Note: Ve- rated power

   The generator voltage manual fine tuning range + 0.5%Ve

   2 floating charge regulation.

   0 ~ 5A (control of floating charge batteries) adjustable current.

   The battery voltage DC12 / 24V

   E. quasi state control system:

   Automatic pre heating system

   Output voltage AC220V

   1.5KW/ output power station

   Automatic control temperature 50 to 55 DEG C (unit temperature)

   In automatic mode, the unit ready to start automatically, power failure, automatically cast net in 8S, with full load operation.   Units must be in the ready state, through the water cooling system of pre heating, self circulation, automatic temperature control, the realization of unit 50 to 55 DEG C.

   F. electric automatic detection:

   In automatic mode, through the external switch signal, to city electricity state automatic long-term detection, discrimination.   Once the city electrical malfunction, power failure, immediately can enter the automatic startup status.

   Automatic start, automatic cast net G. unit, automatic back network, automatic shutdown system:

   When the unit is in the automatic mode, the city power outage with 3S confirmation, automatic start units (three times to start as a circle).   When the rated voltage and rated speed, automatic closing cast net, power supply.   Since the start-up of network power supply time is less than or equal to 12S. When returned to normal after power, with 3S confirmation, set automatic tripping back network, delay time for 3 minutes, automatic shutdown, and automatically enters the ready state automatically start the next.

   H. automatic protection:

   With overload, short circuit, high water temperature, low oil pressure, oil temperature, under voltage, over speed protection.

   With automatic tripping, stop function.

   With overload, high water temperature, low oil pressure, self starting failure, overspeed, oil temperature

   Automatic fault alarm.

   I. system description:

   The system uses high reliability of electrical products, automatic control, automatic start, automatic shutdown and automatic control, industrial computer by Sino foreign joint venture PLC control computer system, ensure the operation reliability.

   The function of automatic switching system, the city electricity, unit two:

   The system has two power city electricity, set automatic switching power supply function, mainly realizes the automatic switching power supply mains and unit.   Normal state, city power supply system has the priority function, when the mains power failure, the system can set automatic switching side, by the unit to the automatic load power supply; when the restoration of normal utility power system, automatic switching of the electric side, municipal electric power to the load automatic power supply, with the City Electric preferred power supply function.

   According to the number of generating units and the city electricity is different, can be divided into: switching single group and one city power switch, single and double electric group switch unit with single, double, double city power switching unit with double city power.   Their functions are as follows:

   Switching A. single group and one of the city power:

   Parameter display function: mains voltage, the generator voltage, load current.

   State display function: normal / fault, generator running / fault, electric / generator load.

   Manual control function: manual / automatic / repair, generator / the city power load.

   Automatic control function: fault, delay confirmation (adjustable time), issued instructions starting unit, unit start normal operation, the generator load; the city electricity recovery, delay confirmation (adjustable time), the city power load, no-load running 3 minutes (adjustable) after the automatic shutdown.

   Switching B. single group and double electricity:

   Parameter display function: a road, two road, the city power voltage mains voltage, the generator voltage, load current.

   Status display: a road normal / fault, two road normal / fault, generator running / fault, a road two road, electric / electric / generator load.

   Manual control function: manual / automatic / repair, master / selection, reserve city electric generator / road two road, electric / electric load.

   Automatic control function: the main use of electricity failure, delay confirmation (adjustable time), the reserve city

   Electric load; two electricity are failure, it sends the starting command, the unit starting back in operation, the generator load; the city electricity recovery, delay confirmation (adjustable time), the city power load, no-load running 3 minutes (adjustable) after the automatic shutdown.

   Switching C. double unit with single city power:

   Parameter display function: mains voltage, voltage, a number of No. two generator generator voltage, load current.

   State display function: normal / fault, a number generator / fault, No. two generator running / fault, the city electricity / number one generator / No. two generator load.

   Manual control function: manual / automatic / repair, main / standby generator, a generator choice / No. two generator / the city power load.

   Automatic control function: fault, delay confirmation (adjustable time), start with the main unit instruction, main unit start running normal load; such as the main units in starting or fault occurs in the process of operation, automatic start standby unit, the normal operation of standby unit after starting with load; city power recovery, delay confirmation (adjustable time), the city power load, no-load operation minutes (adjustable) after the automatic shutdown.

   Switching D. double unit with double electricity:

   Parameter display function: a commercial power voltage, two city road, electric voltage, voltage, a number of No. two generator generator voltage, load current.

   Status display: a road normal / fault, two road normal / fault, a number generator / fault, No. two generator running / fault, a generator / No. two generator / a road in the city of electric / two road in the city of electric load.

   Manual control function: manual / automatic / repair, main / standby generator selection, the active / standby hand city power selection, number one generator / No. two generator / a road in the city of electric / two road in the city of electric load.

   Automatic control function: the main use of electricity failure, delay confirmation (adjustable time), spare the city electricity load; two electricity are failure, delay confirmation (adjustable time), start with the main unit instruction, main unit start running normal load; such as the main units in starting or the fault occurred in the process of operation, automatic start standby unit, the normal operation of standby unit after starting with load; electric recovery, delay confirmation (adjustable time), the city power load, no-load running 3 minutes (adjustable) automatically.

   The system adopts a Sino foreign joint venture love Czech ATS switch, realize electromechanical interlock to ensure reliability of operation.

   Since three, and the car, automatic frequency and load adjustment system function:

   The system has the function of grid connected A. manual / automatic grid / "0" position three sets of system and selection.

   When the system is in the manual car condition, through the realization of two units of manual synchronization table.   Parallel operation, through the automatic frequency and load adjustment device, the realization of the unit operation process of automatic frequency modulation, automatic load regulation.

   When the system is in the "0" state in the automatic mode, the two units in the city after the power failure at the same time start the unit, to realize the automatic cast net power supply only a delay unit, another unit 3 minutes downtime.   If the net unit has been voted the failure occurs, immediately start the other units and cast the net power supply.

   B. when the system is in the automatic and state: in automatic mode two units in the city after the power failure and start the unit, to realize the automatic cast net armor units, when the power load is smaller than a rated power, delay B unit 3 minutes downtime, when a unit has been in operation for 8 hours of continuous work, B units will start immediately, achieve two units of automatic synchronization, and the power supply load is transferred to the second unit, a unit from a network, and a 3 minute delay shutdown.

   C. when the power supply load for 1 minutes more than a rated power, the other units will start immediately and grid connected power supply.   The frequency and load control device to ensure the two units of uniform distribution of load.

   This function can be programmed according to user requirements.

   The D. system and it is the reverse power protection.   The system uses high reliability of electrical products, automatic control, automatic start, automatic cast net, automatic back network, automatic shutdown and automatic control, industrial computer using industrial control computer PLC system, ensure the operation reliability.

   E. automatic paralleling device, automatic frequency and load adjustment device, adopts the quality reliable products.

   Note: the above is the automatic diesel generator, and the vehicle, switch all the functions introduced, specific customer type selection were arranged according to customer needs.   Our company will provide you with the perfect dedicated to automated configuration, your satisfaction is our greatest pursuit of the company!

 
\\\\

GFZ series automatic diesel generating set

Product description:

 

     Automatic diesel generating set It is designed with the advanced control system, using special program controller, and advanced ATS as the core of the high performance digital, automatic generating sets.   Products from the 10KW-5000KW units in the unattended condition automatically realize start-up and shutdown, automatic switching electricity and electricity network, automatic monitoring the running state of equipment, product technology, reliable quality and superior performance, over the years the products become the leader in automation units, exports of the country come out in front.

   Introduces the performance

1, automatic start and input function

   When the city electricity grid to stop power supply or mains voltage or less than 80% of the rated value unit will start automatically, after a successful start-up, to supply the power to the load, the entire process of successful control within 15 seconds of a start, having a distal end interface, can set the start delay, the realization of generating unit start and stop automatically.

  2, automatic exit function 

Generator power output from during the automatic state, if the city electricity recovery and after 30 seconds after the confirmation, unit start executing automatically exit the program, set will be the first to cut off the load, recovery of electric power supply, and cooler running automatically stop after 2 minutes.   If the cooler during the operation, the city power to stop power supply, is set automatically adjustable high speed, on the recovery of load power supply.

  3, alarm in advance / fault protection function 

Low battery voltage, charge failure, over current, low oil pressure, water temperature higher with early warning function, i.e. not numerical stop in alarm, alarm light flashes at this time; when the value exceeds the value of the oil machine downtime, and downtime fault generated.

Low speed, speed, frequency of out of gauge, voltage limit, emergency stop, failed to start a fault protection function, if an analog input value is greater than or less than the lower limit upper limit, corresponding to the high / low start delay, delay after the end, numerical throw did not return to normal, oil machine immediately fault shutdown, warning light on.

   The above all kinds of alarm signal has the self-locking function, only the scene personnel after troubleshooting, press the "stop" button will make the system back to normal.

4, automatic charging function  

Since the power unit in electric or period, automatic charging of battery for starting control.   The charging system uses switch power supply, it can realize two stage charging method of battery.   In the first stage of charging, the battery capacity is low, using 6ADC with constant current charging, when the battery voltage to the 26.5VDC to the constant voltage charging, and remained floating charge.   When the battery was fully charged, the charging current automatic zero.

  5, the manual function 

The unit control system panel has automatic and manual, when system is working in manual state, can be realized on the start-up, high and low speed loaded, power supply, stop, alarm signal lamp test alarm since lifting the power opening and closing, the closing operation, electric.   Emergency stop knobs are effective in automatic and manual state.   Very urgent situation, do not use this button.

   6, other functional overview

   The use of animation icon type alarm, fault display, high brightness, multicolor liquid crystal display parameters; automatic recording unit running time; compact and reasonable structure, stable and reliable performance.

低噪音系列柴油發(fā)電機(jī)組濟(jì)柴系列柴油發(fā)電機(jī)組濰柴動(dòng)力系列燃?xì)獍l(fā)電機(jī)組

聯(lián)系我們

  • 手機(jī):15244128777
  • 電話:0538-6270899
  • 郵箱:talcfd@163.com
  • 公司地址:山東省泰安市高新技術(shù)開發(fā)區(qū)南天門大街3668號(hào)山東蘭電
  • 銷售公司泰安市長城路時(shí)代明珠商務(wù)大廈

泰安蘭馳發(fā)電設(shè)備有限公司

  • 電話:15244128777
  • 傳真:0538-6212877
  • 座機(jī):0538-6270899
  • 地址:山東省泰安市高新技術(shù)開發(fā)區(qū)南天門大街3668號(hào)山東蘭電
  • 銷售公司:泰安市長城路時(shí)代明珠商務(wù)大廈
  • 版權(quán)所有 © 2021  泰安蘭馳發(fā)電設(shè)備有限公司
關(guān)注我們